Muratec F-565 Spécifications Page 366

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 383
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 365
5-76
ADF registration (side)
1.401.251.000.750.55
0.300.250.200.150.10
Test Chart
A
Edge of
the paper
Note: This adjustment must be made after the adjustments of printer registration (top and side) of the 1st cassette
and ADF zoom adjustments (vertical and horizontal) have been made.
Standard Adjustment Tool Setting Range
0 ± 2.9 (mm) Machine parameter:010
– 10.76 ~10.76 (mm)
(0.0847 mm step)
Adjustment procedure
1. Load legal (for USA version) or A4 (for GBR version) size paper to the 1st cassette.
2. Place the Muratec Test Chart No. 2003-01 on the ADF.
3. Make a copy of it in the 1st cassette with 100 % magnification.
4. Check that the difference of width A and the copy of A (A’) meets the specifications.
If the difference falls outside the specified range, perform the following steps to make the adjust-
ment.
5. Enter Machine Parameter mode. (Press <Setting>, <*>, <0>, <0>)
6. Adjust the setting of Machine Parameter 010 to meet the specification.
If the width A is shorter than the standard, decrease value.
If the width A is longer than the standard, increase value.
Vue de la page 365